Updated:
Yegor Kanakhin — FI(S), Alpine Soaring, Vinon-sur-Verdon (LFNF), France
I am a flight instructor, not an examiner. This guide describes our experience at Alpine Soaring in southern France, where we offer intensive individual SPL training with a dedicated instructor, in English. The examiner’s briefing, current rules and aircraft flight manual take precedence.
How do you know you are ready for the SPL skill test?
Completing the syllabus and logging the required hours does not automatically make you ready. The best sign is that you can prepare a glider, launch, centre several thermals, navigate away from home and return safely without constant prompts.
The priorities are Aviate — Navigate — Communicate: fly first, know where you are and which limits apply, then keep others informed. When handling becomes natural, attention is freed for navigation and look-out. In the final weeks I recreate exam conditions: the student plans the flight, makes decisions and explains intentions; I intervene when necessary.
What are the four sections of the SPL practical exam?
Under Part-SFCL, SFCL.145 , the applicant demonstrates the procedures and manoeuvres appropriate to the privileges sought. The French DSAC examination page and 31FormExa describe the assessment.
---------------------------------------------------------------------------------------------------
Section Assessment
--------------------------------------- ------------------------------------------------------------
1. Pre-flight operations and take-off Documents, weather, NOTAM, mass and balance, inspection and checks
2. Launch method Aerotow, winch or self-launch, as applicable; signals and safety procedures
3. Handling Straight flight, turns, slow flight, stalls, spin-related exercises and navigation
4. Circuit, approach and landing Joining, checks, approach control and precision landing
-----------------------------------------------------------------------------------------------------
The sequence may change according to conditions and the examiner’s briefing.
Registration and examiner independence in France
After training, the DTO or ATO issues the practical training attestation and recommendation. At Vinon the chief instructor proposes a primary and reserve examiner for DSAC designation. We wait for the authority’s response and select a date within its validity, together with the candidate and examiner, favouring suitable weather. The glider is booked in advance.
Under SFCL.405(a), an examiner cannot conduct an initial skill test for a candidate to whom they provided more than 50% of the required flight instruction; objectivity must also be protected. See the EASA rules and DSAC forms.
Meeting the examiner
At the clubhouse we check identities, the examiner’s credentials and designation, and the candidate’s documents. The examiner explains the test. They assess your performance, not try to catch you out. Fly independently with the examiner aboard. I recommend briefly explaining significant decisions when workload permits: why you release, leave a thermal or change the route.
Ground examination: documents, weather and route
At Vinon the ground session is often split around the daily club briefing. Collect the carnet de route from the secretariat. Review entries, defects and restrictions, registration, insurance, certificate of airworthiness and ARC, radio station documentation, flight manual and mass-and-balance data. Ask the examiner’s weight and calculate loading using the aircraft’s approved limits. Bring current charts and the regional landing-field guide used by the club.
Prepare weather using Météo-France or Météo-Parapente, and official NOTAM and airspace information from SIA. SkySight is optional. A local example is a planned 100–150 km flight via Vinon, Puimoisson and Saint-Auban, with a possible launch around 12:30–13:00 if conditions suit. A conservative planning glide ratio of 20–21 may be appropriate, but must account for the aircraft, wind, terrain and margins. Identify alternatives throughout the route. The plan is not a commitment; no fixed distance is imposed for the test itself.
Airspace questions during the SPL exam
Expect questions about classes, P/R/D areas, flight levels, frequencies and military activity around Salon. The R71 area illustrates why you must check the next airspace boundary before reaching it. A flight level is a pressure surface, not a fixed altitude above sea level. Check the current AIP, VAC and NOTAM rather than relying on a remembered ceiling. Oral questions may also cover flight principles, performance, operating procedures and navigation.
Glider pre-flight inspection during the SPL exam
About half an hour before departure, the candidate inspects the glider while the examiner observes. Follow the aircraft-specific sequence: cockpit, wing and control connections, correct control response, harness, instruments, airbrakes and trim. Check FLARM status according to the installed model. Secure the canopy against wind. Walk around the aircraft, checking tyres, surfaces, hinges, airbrake bays, pitot/static openings, tail attachment and rudder connections as applicable. Repeat on the other wing. Report findings; resolve any airworthiness doubt before flight. At Vinon we expect closed shoes, sunglasses, a hat and the required parachute equipment.
Take-off and CRIS
CRIS covers Controls, Radio, Instruments and Safety. Read it aloud and perform the checks. Include a safety briefing for launch interruption, tailored to the aircraft, runway, wind and available landing options. For our aerotow procedure, the final checks include a taut rope, airbrakes closed and locked, readiness signal and left hand on the yellow release handle at the appropriate stage. Follow the instructor’s approved procedure and flight manual. The full CRIS card is available in the resources download.
Example radio check: “Romeo Yankee, Delta Zero Nine, radio check.” Reply: “Delta Zero Nine, Romeo Yankee, read you five.” Use the actual callsigns and applicable frequency.
Aerotow, soaring and the SPL flight exercises
During aerotow the examiner observes positioning, control, look-out and awareness of landing options. Release only when the circumstances allow safe continuation. If the first thermal fails, returning safely or making another launch may be the right decision. Join occupied thermals in the established direction and maintain separation. Observe applicable VMC minima under SERA.5001, which depend on airspace and altitude; do not enter cloud on this VFR test.
EASA guidance in GM1 SFCL.430 gives an indicative 30 minutes or three launches for a skill test, with time for briefing and debriefing. At Vinon flights often last about an hour. The examiner may rearrange the route and exercises or request another flight.
Handling items include straight flight, medium turns around 30°, turns to headings, slow flight, stall and recovery, spin-related exercises, steep turns and local navigation. Clear the airspace, especially below, and use sufficient height and the approved aircraft procedures. The examiner determines which demonstrations are appropriate under the official test programme and conditions.
Selecting an outlanding field: VERDO
The examiner may ask you to select a field and explain your reasoning without actually landing there. VERDO covers wind, surface condition, relief, dimensions and obstacles. Select early and reassess continuously: a field in a catalogue is not necessarily usable today. The full card is available in the resources.
Approach and landing during the SPL skill test: TVBCR
Before joining, collect wind, runway and traffic information. TVBCR covers landing gear and traffic, wind and speed (and flaps if fitted), ballast, harness and trim, and radio. Secure loose objects. Set approach speed and configuration using the flight manual and conditions, not a universal formula. Complete checks before workload increases.
Illustrative Vinon calls: “Vinon, Delta Zero Nine, request runway in use”; “Vinon, Delta Zero Nine, entering the descending area, runway two eight”; “Vinon, Delta Zero Nine, right downwind runway two eight, gear down and locked.” French example: « Vinon, Delta Zéro Neuf, vent arrière droite piste deux huit, train sorti verrouillé. » Check the current VAC and local phraseology; radio silence does not mean the circuit is clear.
On final, I teach three priorities: axis — speed — aiming point. Control the approach, touchdown and rollout until the glider stops. Precision landing may simulate a short field. The examiner assesses the complete sequence, not only touchdown.
Assessment criteria, common mistakes and renoncement
The FFVP examiner guidance (Actions vitales! No. 19, May 2021, Sécurité des vols) addresses technical and non-technical skills. Assessment includes bank and speed tolerances for turns, slow flight, final approach and a designated touchdown zone. Use the current assessment grid rather than treating numerical examples as universal limits.
My recurring observations are insufficient head movement before and during turns, poor communication, skipped or merely recited checks, and stress. FLARM cannot replace visual look-out. Stress narrows attention; remind yourself that you already know these exercises. Serious safety violations may end the test.
French gliding culture calls the deliberate abandonment of an unsafe plan renoncement. If the forecast fails, shorten the route, return, postpone an exercise or choose an alternative landing site. Do not continue merely because an examiner is behind you. Knowing your own limits is a quality of a pilot-in-command, not weakness.
Results, licence paperwork and the Vinon tradition
Under SFCL.145, passing all sections means a pass; failing one section requires repeating that section; failing more than one requires repeating the full test. Failure of any section on a retest requires repeating the whole test. Further training is required after two unsuccessful attempts. A weather interruption is not automatically a failure.
The examiner debriefs and completes the report. French forms include 18FormExa (training and recommendation), 52FormExa (registration) and 31FormExa (test report and provisional attestation). Consult the DSAC page. The provisional attestation may be valid for up to eight weeks; check its privileges, territorial scope and expiry. Do not fly on an expired attestation. Follow your licence application.
At Vinon we celebrate milestones with a barbecue on the club terrace: a new SPL, a new glider type, flaps or local mountain zones T1–T3. The licence is a beginning, not the end of learning.
Preparing for the SPL practical exam
Practise independent flight preparation, spoken checks, radio communication, look-out, field selection and precision landings. Rehearse launch-interruption briefings with your instructor. Sleep well and arrive relaxed. You have already learned to fly; enjoy showing what you can do.
Frequently asked questions
How long does the SPL skill test take?
Several hours including ground preparation and debrief; flight guidance is about 30 minutes or three launches.
Can my instructor examine me?
Only if qualified as FE(S), objective and compliant with SFCL.405, including the 50% instruction limit.
Must I pass theory first?
Yes; the practical test also checks application of theoretical knowledge.
Is a fixed cross-country distance required?
No fixed distance is imposed for the skill test itself.
What if I cannot climb after release?
Return safely if appropriate; another launch may be arranged.
Can an outlanding be assessed?
Yes, field selection may be assessed using VERDO. A safe outlanding is not automatically a failure.
What if I fail one section?
Repeat that section under SFCL.145; more than one failed section requires a full retest.
Can weather postpone the test?
Yes, unsafe conditions justify postponement or interruption.
Can I take the SPL exam in English in France?
Alpine Soaring offers English-language training. Confirm the examination language with the designated examiner in advance, and check radio requirements separately.
Can I fly immediately after passing?
Only within valid provisional privileges, with medical fitness and all applicable conditions met.
Is a French SPL recognised elsewhere in EASA?
Yes, subject to the applicable privileges and operating requirements.
Download the pilot checklists
These aids do not replace the flight manual or school procedures.
CRIS (take-off),
TVBCR (landing),
VERDO (field selection):
What comes after the SPL?
Explore our training and further privileges:
- Stage 1 — First solo
- Stage 2 — SPL licence
- TMG
Sources and further reading
- EASA Easy Access Rules — SFCL.145, SFCL.405, GM1 SFCL.430, SERA.5001.
- DSAC — Épreuve pratique SPL — 31FormExa.
- SIA — AIP, VAC, NOTAM.
